    Selection and ordering data

    The following tables list recommendations for additional line-side components, such as fuses and circuit breakers. The values in the table take into account the overload capability of the inverter.

    Notes for use in compliance with IEC standards:

    3NA3 or 3NE1 fuses and 3RV motor starter protectors or 3VL circuit breakers are recommended for European countries.

    Notes for use in compliance with UL regulations:

    UL-listed fuses Class J, T, CC, G or CF (with rated voltage 250 V AC or 600 V AC) or 3NE1 (UL-compliant – corresponds to RU) are required for North America.

    Short Circuit Current Rating (SCCR)
    according to UL
    Applies to industrial control panel installations to NEC Article 409 or UL 508A/508C

    • PM240-2: 100 kA (200 V versions), 100 kA (400 V versions), 65 kA (690 V versions)
      (the value depends on the fuses and circuit breakers used)

    Notes regarding installations in Canada:

    Overvoltage protection devices in accordance with overvoltage category III and with the following ratings must be connected on the line side of the inverter:

    • Rated voltage 480 V (phase-phase) and 480 V (phase-ground)
    • Voltage limit 4 kV (phase-phase) and 6 kV (phase-ground)

    All overvoltage protection devices used must comply with Canadian standards for industrial installations.

    Further information, particularly regarding use in accordance with UL guidelines, is available at
    https://support.industry.siemens.com/cs/document/109479152

    https://support.industry.siemens.com/cs/document/109486009

    Additional information about the line-side power components can be found in Catalogs LV 10, IC 10 and IC 10 AO as well as the Industry Mall.

    Type rating 1)

    PM240-2 Power Module
    standard variant

    IEC-compliant

    UL/cUL-compliant

     

     

     

     

    Fuse

    Circuit breaker

    Fuse type
    Rated voltage 250 V AC or 600 V AC

     

     

    Type

     

    Current

     

     

     

    Current

    kW

    hp

    6SL3210-...

    Frame size

    A

    Article No.

    Article No.

    Class

    A

    200 ... 240 V 1 AC/3 AC

    0.55

    0.75

    1PB13-0 . L0

    FSA

    16

    3NA3805

    3RV2011-4AA10

    J, T, CC, G, CF

    15

    0.75

    1

    1PB13-8 . L0

    FSA

    16

    3NA3805

    3RV2011-4AA10

    J, T, CC, G, CF

    15

    1.1

    1.5

    1PB15-5 . L0

    FSB

    32

    3NA3812

    3RV2021-4EA10

    J, T, CC, G, CF

    35

    1.5

    2

    1PB17-4 . L0

    FSB

    32

    3NA3812

    3RV2021-4EA10

    J, T, CC, G, CF

    35

    2.2

    3

    1PB21-0 . L0

    FSB

    32

    3NA3812

    3RV2021-4EA10

    J, T, CC, G, CF

    35

    3

    4

    1PB21-4 . L0

    FSC

    50

    3NA3820

    3RV1031-4HA10

    J, T, CC, G, CF

    50

    4

    5

    1PB21-8 . L0

    FSC

    50

    3NA3820

    3RV1031-4HA10

    J, T, CC, G, CF

    50

    200 ... 240 V 3 AC

    5.5

    7.5

    1PC22-2 . L0

    FSC

    50

    3NA3820

    3RV1031-4HA10

    J, T, CC, G, CF

    50

    7.5

    10

    1PC22-8 . L0

    FSC

    50

    3NA3820

    3RV1031-4HA10

    J, T, CC, G, CF

    50

    11

    15

    1PC24-2UL0

    FSD

    63

    3NE1818-0

    3RV1041-4JA10

    J

    60

    15

    20

    1PC25-4UL0

    FSD

    80

    3NE1820-0

    3RV1041-4KA10

    J

    70

    18.5

    25

    1PC26-8UL0

    FSD

    100

    3NE1021-0

    3RV1041-4LA10

    J

    90

    22

    30

    1PC28-0UL0

    FSE

    100

    3NE1021-0

    3VL1712-2DD33-....

    *)

    J

    100

    30

    40

    1PC31-1UL0

    FSE

    160

    3NE1224-0

    3VL1716-2DD33-....

    *)

    J

    150

    37

    50

    1PC31-3UL0

    FSF

    200

    3NE1225-0

    3VL3720-3DC33-....

    *)

    J

    175

    45

    60

    1PC31-6UL0

    FSF

    200

    3NE1225-0

    3VL3720-3DC33-....

    *)

    J

    200

    55

    75

    1PC31-8UL0

    FSF

    250

    3NE1227-0

    3VL3725-3DC33-....

    *)

    J

    225

    380 ... 480 V 3 AC

    0.55

    0.75

    1PE11-8 . L1

    FSA

    16

    3NA3805

    3RV2011-4AA10

    J, T, CC, G, CF

    10

    0.75

    1

    1PE12-3 . L1

    FSA

    16

    3NA3805

    3RV2011-4AA10

    J, T, CC, G, CF

    10

    1.1

    1.5

    1PE13-2 . L1

    FSA

    16

    3NA3805

    3RV2011-4AA10

    J, T, CC, G, CF

    15

    1.5

    2

    1PE14-3 . L1

    FSA

    16

    3NA3805

    3RV2011-4AA10

    J, T, CC, G, CF

    20

    2.2

    3

    1PE16-1 . L1

    FSA

    16

    3NA3805

    3RV2011-4AA10

    J, T, CC, G, CF

    30

    3

    4

    1PE18-0 . L1

    FSA

    16

    3NA3805

    3RV2011-4AA10

    J, T, CC, G, CF

    30

    4

    5

    1PE21-1 . L0

    FSB

    32

    3NA3812

    3RV2021-4EA10

    J, T, CC, G, CF

    35

    5.5

    7.5

    1PE21-4 . L0

    FSB

    32

    3NA3812

    3RV2021-4EA10

    J, T, CC, G, CF

    35

    7.5

    10

    1PE21-8 . L0

    FSB

    32

    3NA3812

    3RV2021-4EA10

    J, T, CC, G, CF

    35

    11

    15

    1PE22-7 . L0

    FSC

    50

    3NA3820

    3RV1031-4HA10

    J, T, CC, G, CF

    50

    15

    20

    1PE23-3 . L0

    FSC

    50

    3NA3820

    3RV1031-4HA10

    J, T, CC, G, CF

    50

    18.5

    25

    1PE23-8 . L0

    FSD

    63

    3NE1818-0

    3RV1041-4JA10

    J

    60

    22

    30

    1PE24-5 . L0

    FSD

    80

    3NE1820-0

    3RV1041-4KA10

    J

    70

    30

    40

    1PE26-0 . L0

    FSD

    100

    3NE1021-0

    3RV1041-4LA10

    J

    90

    37

    50

    1PE27-5 . L0

    FSD

    100

    3NE1021-0

    3RV1041-4MA10

    J

    100

    45

    60

    1PE28-8 . L0

    FSE

    125

    3NE1022-0

    3VL1712-2DD33-....

    *)

    J

    125

    55

    75

    1PE31-1 . L0

    FSE

    160

    3NE1224-0

    3VL1716-2DD33-....

    *)

    J

    150

    75

    100

    1PE31-5 . L0

    FSF

    200

    3NE1225-0

    3VL3720-3DC33-....

    *)

    J

    200

    90

    125

    1PE31-8 . L0

    FSF

    250

    3NE1227-0

    3VL3725-3DC33-....

    *)

    J

    225

    110

    150

    1PE32-1 . L0

    FSF

    315

    3NE1230-0

    3VL4731-3DC36-....

    *)

    J

    300

    132

    200

    1PE32-5 . L0

    FSF

    350

    3NE1331-0

    3VL4740-3DC36-....

    *)

    J

    350

    500 ... 690 V 3 AC

    11

    10

    1PH21-4 . L0

    FSD

    25

    3NE1815-0

    3RV1042-4BA10

    J

    20

    15

    15

    1PH22-0 . L0

    FSD

    25

    3NE1815-0

    3RV1042-4EA10

    J

    25

    18.5

    20

    1PH22-3 . L0

    FSD

    35

    3NE1803-0

    3RV1042-4EA10

    J

    30

    22

    25

    1PH22-7 . L0

    FSD

    35

    3NE1803-0

    3VL1704-2DD33-....

    *)

    J

    35

    30

    30

    1PH23-5 . L0

    FSD

    50

    3NE1817-0

    3VL1705-2DD33-....

    *)

    J

    45

    37

    40

    1PH24-2 . L0

    FSD

    63

    3NE1818-0

    3VL1706-2DD33-....

    *)

    J

    60

    45

    50

    1PH25-2 . L0

    FSE

    80

    3NE1820-0

    3VL1708-2DD33-....

    *)

    J

    80

    55

    60

    1PH26-2 . L0

    FSE

    80

    3NE1820-0

    3VL1710-2DD33-....

    *)

    J

    80

    75

    75

    1PH28-0 . L0

    FSF

    100

    3NE1021-0

    3VL1712-2DD33-....

    *)

    J

    100

    90

    100

    1PH31-0 . L0

    FSF

    125

    3NE1022-0

    3VL1712-2DD33-....

    *)

    J

    125

    110

    100

    1PH31-2 . L0

    FSF

    160

    3NE1224-0

    3VL1716-2DD33-....

    *)

    J

    150

    132

    125

    1PH31-4 . L0

    FSF

    200

    3NE1225-0

    3VL3720-3DC33-....

    *)

    J

    200



    1) Type rating based on the rated output current Irated. The rated output current Irated is based on the duty cycle for low overload (LO).

    *) See Catalog LV 10 for Article No. supplements.

    Type rating 1)

    PM240‑2 Power Module
    push-through variant

    IEC-compliant

    UL/cUL-compliant

     

     

     

     

    Fuse

    Circuit breaker

    Fuse type
    Rated voltage 250 V AC or 600 V AC

     

     

    Type

     

    Current

     

     

     

    Current

    kW

    hp

    6SL3211-...

    Frame size

    A

    Article No.

    Article No.

    Class

    A

    200 ... 240 V 1 AC/3 AC

    0.75

    1

    1PB13-8 . L0

    FSA

    16

    3NA3805

    3RV2011-4AA10

    J, T, CC, G, CF

    15

    2.2

    3

    1PB21-0 . L0

    FSB

    32

    3NA3812

    3RV2021-4EA10

    J, T, CC, G, CF

    35

    4

    5

    1PB21-8 . L0

    FSC

    50

    3NA3820

    3RV1031-4HA10

    J, T, CC, G, CF

    50

    380 ... 480 V 3 AC

    3

    4

    1PE18-0 . L1

    FSA

    16

    3NA3805

    3RV2011-4AA10

    J, T, CC, G, CF

    30

    7.5

    10

    1PE21-8 . L0

    FSB

    32

    3NA3812

    3RV2021-4EA10

    J, T, CC, G, CF

    35

    15

    20

    1PE23-3 . L0

    FSC

    50

    3NA3820

    3RV1031-4HA10

    J, T, CC, G, CF

    50



    1) Type rating based on the rated output current Irated. The rated output current Irated is based on the duty cycle for low overload (LO).