SIPLUS extreme RAIL analog input modules

  • Заказные данные
    (2)
  • Аксессуары
    (5)
  • Информационные материалы

    Информационные материалы

    • 4-channel analog input (AI) modules
    • Approved in accordance with the EN 50155, EN 15121, EN 50124, EN 50125 and EN 45545 railway standards for use in rail traffic

    For different requirements, the digital output modules offer:

    • BaseUnits for single or multiple-conductor connection with automatic slot coding
    • Individual system-integrated load group formation with self-assembling voltage distribution bars (a separate power module is no longer required for ET 200SP)
    • Option of connecting current, voltage and resistance sensors, as well as thermocouples
    • Energy Meter for recording up to 200 electrical variables
    • Clear labeling on front of module
    • LEDs for diagnostics, status, supply voltage and faults
    • Electronically readable and non-volatile writable rating plate (I&M data 0 to 3)
    • Optional accessories
      • Labeling strips (film or card)
      • Equipment labeling plate
      • Color-coded label with module-specific CC Code
      • Shielding terminal

    A quick and clear comparison of the functions of the AI modules is offered by the TIA Selection Tool.

    Overview of analog input modules

    Analog input

    PU

    Article No.

    CC-Code

    BU type

    AI 4 x I 2/4-wire ST

    1

    6AG2134-6GD00-4BA1

    CC03

    A0, A1

    AI Energy Meter ST

    1

    6AG2134-6PA00-4BD0

    CC00

    D0



    Overview of BaseUnits

    BaseUnit

    PU

    Article No.

    CC-Codes for process terminals

    CC-Codes for AUX terminals

    BU type A0

    • New load group (light)
    • 16 process terminals
    • With 10 AUX terminals

    1

    6AG2193-6BP20-4DA0

    CC01 to CC05

    CC71 to CC73

    BU type A0

    • New load group (light)
    • 16 process terminals
    • Without AUX terminals

    1

    6AG2193-6BP00-4DA0

    CC01 to CC05

    --

    BU type A0

    • Forwarding of load group (dark)
    • 16 process terminals
    • With 10 AUX terminals

    1

    6AG2193-6BP20-4BA0

    CC01 to CC05

    CC71 to CC73

    BU type A0

    • Forwarding of load group (dark)
    • 16 process terminals
    • Without AUX terminals

    1

    6AG2193-6BP00-4BA0

    CC01 to CC05

    --

    BU type D0

    • Forwarding of load group (dark)
    • 12 process terminals
    • Without AUX terminals

    1

    6AG2193-6BP00-4BD0

    --

    --



    Область применения

    The measured values of analog sensors (current, voltage, resistance, temperature etc.) can be recorded and transferred to the higher-level controller via the analog input modules.

    Дизайн

    Usable BaseUnits (BU)

    BaseUnits with an appropriate number of terminals are available for single or multi-conductor connection.

    All variants that correspond to the BU type of the I/O module used can be used as BaseUnits (see Selection and ordering data).

    Load group formation

    A light-colored BU separates the self-assembling, internal voltage buses (P1, P2, AUX) and thus opens a new load group. The supply voltage of a load group must be fed in at the light BU of this load group.

    A dark BU forwards the supply voltage of the adjacent light BU on the left via the self-assembling voltage buses P1, P2 and AUX. A new infeed is therefore only required on the next light BU to the right. The setting of a further light BU is required whenever

    • a new load group is to be formed (for example, for isolating the supply voltage from module groups) or
    • the maximum current simultaneously required by the load group exceeds the permissible limit of 10 A.
    Color identification of the terminals

    The potentials at the terminals of the BaseUnit are defined by the inserted I/O module in each case. To prevent wiring faults, the potentials of the terminals can optionally be identified by means of module-specific color-coded labels. The color-coded label that matches the respective I/O module is defined by the color code CCxx of the I/O module. This color code is also printed on the front of the module.

    In BaseUnits with the additional ten internally jumpered AUX terminals or 2x5 additional terminals, these can also be identified with color-coded labels. For the ten AUX terminals, color-coded labels are available in red, blue, and yellow/green.

    Labeling

    Labeling strips

    Labeling strips can be inserted on the front of the interface modules or I/O modules and individually labeled by means of STEP7, macros, etc. No special additional holder is required. If required, they can be easily replaced with the component.

    Equipment labeling plates

    Equipment labeling plates enable the equipment to be easily identified (e.g. compliant with EN 81346). They are easily plugged onto the required component (interface modules, I/O modules and BaseUnits) and when required, they can be easily replaced with the component.

    The following labeling components are available:

    Film labeling strips, light-gray, roll with 500 strips, perforated, for thermal transfer printers

    • Film labeling strips, yellow, roll with 500 strips, perforated, for thermal transfer printers
    • Card labeling strips (180 g/m2), light gray, DIN A4 sheets with 100 strips each, perforated, for laser printer
    • Card labeling strips (180 g/m2), yellow, DIN A4 sheets with 100 strips each, perforated, for laser printer
    • Equipment labeling plates, white, ten sheets each with 16 labels, for thermal transfer card printers or labels
    System-integrated shielded connection

    For the space-saving and EMC-optimized connection of cable shields, a shield connection is available that is quick and easy to mount. This consists of one shield connection element that can be plugged onto the BaseUnit and one shield terminal for each module. The low-impedance connection to the functional ground (DIN rail) is achieved without any additional wiring by the user.

    Технические данные

    Order number

    6AG2134-6GD00-4BA1

    SIPLUS ET 200SP AI 4XI 2-/4-WIRE TX RAIL

    General information

     

    Product type designation

    AI 4xI 2-/4-wire ST

    Product function

     

    • I&M data

    Yes; I&M0 to I&M3

    • Measuring range scalable

    No

    Operating mode

     

    • Oversampling

    No

    • MSI

    No

    CiR – Configuration in RUN

     

    Reparameterization possible in RUN

    Yes

    Calibration possible in RUN

    No

    Supply voltage

     

    Type of supply voltage

    DC

    Rated value (DC)

    24 V

    Reverse polarity protection

    Yes

    Analog inputs

     

    Number of analog inputs

    4; > 60 °C max. 1x +/- 20 mA permissible

    permissible input current for current input (destruction limit), max.

    50 mA

    Cycle time (all channels), min.

    Sum of the basic conversion times and additional processing times (depending on the parameterization of the active channels)

    Input ranges (rated values), currents

     

    • 0 to 20 mA

    Yes

    • -20 mA to +20 mA

    Yes

    • 4 mA to 20 mA

    Yes

    Cable length

     

    • shielded, max.

    1 000 m

    Analog value generation for the inputs

     

    Integration and conversion time/resolution per channel

     

    • Resolution with overrange (bit including sign), max.

    16 bit

    • Integration time, parameterizable

    Yes

    • Interference voltage suppression for interference frequency f1 in Hz

    16.6 / 50 / 60 Hz

    • Conversion time (per channel)

    180 / 60 / 50 ms

    Smoothing of measured values

     

    • Number of smoothing levels

    4; None; 4/8/16 times

    • parameterizable

    Yes

    Encoder

     

    Connection of signal encoders

     

    • for voltage measurement

    No

    • for current measurement as 2-wire transducer

    Yes

    • Burden of 2-wire transmitter, max.

    650 Ω

    • for current measurement as 4-wire transducer

    Yes

    Errors/accuracies

     

    Basic error limit (operational limit at 25 °C)

     

    • Current, relative to input range, (+/-)

    0.3 %

    Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency

     

    • Series mode interference (peak value of interference < rated value of input range), min.

    70 dB

    • Common mode voltage, max.

    10 V

    • Common mode interference, min.

    90 dB

    Isochronous mode

     

    Isochronous operation (application synchronized up to terminal)

    No

    Interrupts/diagnostics/status information

     

    Diagnostics function

    Yes

    Alarms

     

    • Diagnostic alarm

    Yes

    • Limit value alarm

    No

    Diagnostic messages

     

    • Monitoring the supply voltage

    Yes

    • Wire-break

    Yes; at 4 to 20 mA

    • Short-circuit

    Yes; 2-wire mode: Short-circuit of the encoder supply to ground or of an input to the encoder supply

    • Group error

    Yes

    • Overflow/underflow

    Yes

    Diagnostics indication LED

     

    • Monitoring of the supply voltage (PWR-LED)

    Yes; Green LED

    • Channel status display

    Yes; Green LED

    • for channel diagnostics

    No

    • for module diagnostics

    Yes; Green/red LED

    Potential separation

     

    Potential separation channels

     

    • between the channels and backplane bus

    Yes

    Isolation

     

    Isolation tested with

    707 V DC (type test) and according to EN 50155 (routine test)

    Standards, approvals, certificates

     

    Railway application

     

    • EN 50121-3-2

    Yes; EMC for rail vehicles

    • EN 50121-4

    Yes; EMC for signal and telecommunications systems

    • EN 50124-1

    Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC

    • EN 50125-1

    Yes; Rail vehicles - see ambient conditions

    • EN 50125-2

    Yes; Stationary electrical equipment - see ambient conditions

    • EN 50125-3

    Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)

    • EN 50155

    Yes; Rail vehicles - temperature class Tx, horizontal mounting position, salt spray Class ST2

    • EN 61373

    Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B

    • Fire protection acc. to EN 45545-2

    Yes; Rail vehicles - verification on request

    Ambient conditions

     

    Ambient temperature during operation

     

    • horizontal installation, min.

    -40 °C; = Tmin

    • horizontal installation, max.

    70 °C; = Tmax; +85 °C for 10 min (Tx acc. to EN 50155)

    Extended ambient conditions

     

    • relative to ambient temperature-atmospheric pressure-installation altitude

    Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

    Relative humidity

     

    • With condensation, tested in accordance with IEC 60068-2-38, max.

    100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

    Resistance

     

    • against biologically active substances / conformity with EN 60721-3-3

    Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

    • against biologically active substances/conformity with EN 60721-3-5

    Yes; Class 5B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against chemically active substances / conformity with EN 60721-3-3

    Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

    • against chemically active substances/conformity with EN 60721-3-5

    Yes; Class 5C3 (RH < 75%) including salt spray according to EN 50155 (ST2). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against mechanically active substances / conformity with EN 60721-3-3

    Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

    • against mechanically active substances/conformity with EN 60721-3-5

    Yes; Class 5S3 including sand and dust. The supplied plug covers must remain in place over the unused interfaces during operation!

    Dimensions

     

    Width

    15 mm

    Weights

     

    Weight, approx.

    31 g

    Other

     

    Note:

    For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776


    Order number

    6AG2134-6PA00-4BD0

    SIPLUS ET 200SP AI ENERGY METER TX RAIL

    General information

     

    Product type designation

    AI energy meter 400VAC ST

    Product function

     

    • Voltage measurement

    Yes

    • Voltage measurement with voltage transformers

    No

    • Current measurement

    Yes

    • Phase current measurement without current transformers

    No

    • Phase current measurement with current transformers

    Yes

    • Energy measurement

    Yes

    • Frequency measurement

    Yes

    • Power measurement

    Yes

    • Active power measurement

    Yes

    • Reactive power measurement

    Yes

    • I&M data

    Yes; I&M0 to I&M3

    • Isochronous mode

    No

    Operating mode

     

    • cyclic measurement

    Yes

    • acyclic measurement

    Yes

    • Acyclic measured value access

    Yes

    • Fixed measured value sets

    Yes

    • Freely definable measured value sets

    No

    CiR – Configuration in RUN

     

    Reparameterization possible in RUN

    Yes

    Calibration possible in RUN

    No

    Installation type/mounting

     

    Mounting position

    Horizontal

    Supply voltage

     

    Design of the power supply

    Supply via voltage measurement channel L1

    Type of supply voltage

    100 - 240 V AC

    permissible range, lower limit (AC)

    90 V

    permissible range, upper limit (AC)

    264 V

    Line frequency

     

    • permissible range, lower limit

    47 Hz

    • permissible range, upper limit

    63 Hz

    Address area

     

    Address space per module

     

    • Address space per module, max.

    44 byte; 32 byte input / 12 byte output

    Analog inputs

     

    Cycle time (all channels), typ.

    50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data)

    Interrupts/diagnostics/status information

     

    Alarms

     

    • Diagnostic alarm

    Yes

    • Limit value alarm

    No

    • Hardware interrupt

    No

    Diagnostics indication LED

     

    • Monitoring of the supply voltage (PWR-LED)

    Yes

    • Channel status display

    Yes; Green LED

    • for channel diagnostics

    Yes; red Fn LED

    • for module diagnostics

    Yes; green/red DIAG LED

    Integrated Functions

     

    Measuring functions

     

    • Measuring procedure for voltage measurement

    TRMS

    • Measuring procedure for current measurement

    TRMS

    • Type of measured value acquisition

    seamless

    • Curve shape of voltage

    Sinusoidal or distorted

    • Buffering of measured variables

    No

    • Parameter length

    38 byte

    • Bandwidth of measured value acquisition

    2 kHz; Harmonics: 39 / 50 Hz, 32 / 60 Hz

    Operating mode for measured value acquisition

     

    • automatic detection of line frequency

    No; Parameterizable

    Measuring range

     

    • Frequency measurement, min.

    45 Hz

    • Frequency measurement, max.

    65 Hz

    Measuring inputs for voltage

     

    • Measurable line voltage between phase and neutral conductor

    230 V

    • Measurable line voltage between the line conductors

    400 V

    • Measurable line voltage between phase and neutral conductor, min.

    90 V

    • Measurable line voltage between phase and neutral conductor, max.

    264 V

    • Measurable line voltage between the line conductors, min.

    155 V

    • Measurable line voltage between the line conductors, max.

    460 V

    • Measurement category for voltage measurement in accordance with IEC 61010-2-030

    CAT II; CAT III in case of guaranteed protection level of 1.5 kV

    • Internal resistance line conductor and neutral conductor

    3.4 MΩ

    • Power consumption per phase

    20 mW

    • Impulse voltage resistance 1,2/50µs

    1 kV

    Measuring inputs for current

     

    • measurable relative current (AC), min.

    5 %; Relative to the secondary rated current; 1 A, 5 A

    • measurable relative current (AC), max.

    100 %; Relative to the secondary rated current; 1 A, 5 A

    • Continuous current with AC, maximum permissible

    5 A; at > +60 °C max. permissible current 1 A per phase

    • Apparent power consumption per phase for measuring range 5 A

    0.6 V·A

    • Rated value short-time withstand current restricted to 1 s

    100 A

    • Input resistance measuring range 0 to 5 A

    25 mΩ

    • Zero point suppression

    Parameterizable: 20 - 250 mA, default 50 mA

    • Surge strength

    10 A; for 1 minute

    Accuracy class according to IEC 61557-12

     

    • Measured variable voltage

    0.5

    • Measured variable current

    0.5

    • Measured variable apparent power

    1

    • Measured variable active power

    1

    • Measured variable reactive power

    1

    • Measured variable power factor

    0.5

    • Measured variable active energy

    1

    • Measured variable reactive energy

    2

    • Measured variable phase angle

    ±1 °; not covered by IEC 61557-12

    • Measured variable frequency

    0.05

    Potential separation

     

    Potential separation channels

     

    • between the channels and backplane bus

    Yes; 3 700V AC (type test) CAT III

    Isolation

     

    Isolation tested with

    2 300 V AC for 1 minute (type test) and according to EN 50155 (routine test)

    Standards, approvals, certificates

     

    Railway application

     

    • EN 50121-3-2

    Yes; EMC for rail vehicles

    • EN 50121-4

    Yes; EMC for signal and telecommunications systems

    • EN 50124-1

    Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC

    • EN 50125-1

    Yes; Rail vehicles - see ambient conditions

    • EN 50125-2

    Yes; Stationary electrical equipment - see ambient conditions

    • EN 50125-3

    Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)

    • EN 50155

    Yes; Rail vehicles - temperature class Tx, horizontal mounting position, salt spray Class ST2

    • EN 61373

    Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B

    • Fire protection acc. to EN 45545-2

    Yes; Rail vehicles - verification on request

    Ambient conditions

     

    Ambient temperature during operation

     

    • horizontal installation, min.

    -40 °C; = Tmin

    • horizontal installation, max.

    70 °C; = Tmax; +85 °C for 10 min (Tx acc. to EN 50155)

    Extended ambient conditions

     

    • relative to ambient temperature-atmospheric pressure-installation altitude

    Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

    Relative humidity

     

    • With condensation, tested in accordance with IEC 60068-2-38, max.

    100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

    Resistance

     

    • against biologically active substances / conformity with EN 60721-3-3

    Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

    • against biologically active substances/conformity with EN 60721-3-5

    Yes; Class 5B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against chemically active substances / conformity with EN 60721-3-3

    Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

    • against chemically active substances/conformity with EN 60721-3-5

    Yes; Class 5C3 (RH < 75%) including salt spray according to EN 50155 (ST2). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against mechanically active substances / conformity with EN 60721-3-3

    Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

    • against mechanically active substances/conformity with EN 60721-3-5

    Yes; Class 5S3 including sand and dust. The supplied plug covers must remain in place over the unused interfaces during operation!

    Dimensions

     

    Width

    20 mm

    Weights

     

    Weight (without packaging)

    45 g

    Other

     

    Note:

    For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776

    Data for selecting a current transformer

     

    • Burden power current transformer x/1A, min.

    As a function of cable length and cross section, see device manual

    • Burden power current transformer x/5A, min.

    As a function of cable length and cross section, see device manual