Товаров
  
корзина пуста
  • Каталог оборудования Siemens

SIPLUS S7-400 CPU 412

  • Заказные данные
    (1)
  • Аксессуары
    (17)
  • Информационные материалы

    Информационные материалы

    • The low-cost introduction to the mid performance range
    • Can be used in small and medium-sized plants with requirements in the mid performance range
    Note:

    SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added.

    Technical documentation on SIPLUS can be found here:
    http://www.siemens.de/siplus-extreme

    Область применения

    The CPU 412-1 is the low-cost entry into the medium performance range. It can be used in smaller systems with limited I/O configuration. The combined MPI/DP interface also enables operation of a PROFIBUS DP line.

    The CPU 412-2 is the CPU for applications in the mid-performance range with 2 PROFIBUS DP master systems.

    For networking within a PROFINET network, the CPU 412-2 PN is available.

    Дизайн

    The CPU 412-1, CPU 412-2 and CPU 412-2 PN are equipped with the following:

    • Powerful processor:
      The CPUs achieve instruction execution times as low as 0.75 µs per binary instruction.
    • CPU 412-1: 512 KB main memory (of which 256 KB each for program and data);
      CPU 412-2: 1 MB main memory (of which 512 KB each for program and data);
      CPU 412-2 PN: 1 MB main memory (of which 512 KB each for program and data);
      fast main memory for parts of the user program relevant to execution.
    • Flexible expansion:
      Up to 65536 digital and 4096 analog inputs/outputs.
    • Multi-point interface MPI:
      The MPI allows a simple network to be established with up to 32 stations and a data transmission rate of up to 12 Mbps. The CPUs can establish up to 16 connections to stations of the communication bus (C bus) and the MPI.
    • Mode selector switch:
      Designed as toggle switch.
    • Diagnostics buffer:
      The last 120 fault and interrupt events are retained in a ring buffer for diagnostic purposes. The number of entries can be parameterized.
    • Real-time clock:
      The date and time are appended to diagnostic messages of the CPUs.
    • Memory card:
      For expansion of the integrated load memory. The information in the load memory comprises S7-400 parameterization data in addition to the program and therefore requires twice as much memory space. The result is:
      • The integral load memory is sufficiently large, so a memory card is often not required.

    The CPU 412-2 also features:

    • PROFIBUS DP interface and combined MPI/DP interface:
      The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user's point of view, the distributed I/O is treated as central I/O (same configuring, addressing, and programming).
    • Mixed configuration:
      SIMATIC S5 and SIMATIC S7 as PROFIBUS master according to EN 50170.

    Функции

    • Block protection:
      A password concept also protects the user program from unauthorized access
    • Integrated HMI services:
      The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
    • Integrated communication functions:
      • PG/OP communication
      • Global data communication
      • S7 standard communication
      • S7 communication
    Programmable properties

    The STEP 7 tool "Hardware configuration" can be used to parameterize the properties and response of the S7-400 including the CPUs, e.g.

    • Multipoint interface MPI:
      • Definition of node addresses
      • Startup/cycle behavior
      • Stipulation of the maximum cycle time and communication load
    • Address allocation:
      Addressing of I/O modules
    • Retentive area:
      Definition of the number of retentive bit memories, counters, timers, data blocks, and clock memories
    • Size of the process image, local data
    • Length of the diagnostics buffer
    • Protection level:
      Definition of access authorizations to program and data
    • System diagnostics:
      Definition of the handling and scope of diagnostics messages
    • Timed interrupts:
      Setting of periodicity
    Display and information functions
    • Status and fault indicators:
      LEDs indicate internal and external faults and operating modes such RUN, STOP, restart, test function, etc.
    • Test functions:
      The PG can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components.
    • Information functions:
      The PG can be used to provide the user with information about the memory capacity and operating mode of the CPU, and the current utilization of the working and load memories.

    Технические данные

    Order number

    6AG1412-2EK06-2AB0

    SIPLUS S7-400 CPU 412-2 PN

    General information

     

    Product type designation

    CPU 412-2 PN

    Engineering with

     

    • Programming package

    STEP 7 V5.5 or higher/iMap V3.0 + iMap STEP 7 Add-on V3.0 SP5 or higher

    Supply voltage

     

    Rated value (DC)

    • 24 V DC

    No; Power supply via system power supply

    Power loss

     

    Power loss, typ.

    5.5 W

    Memory

     

    Work memory

     

    • integrated

    1 Mbyte

    • integrated (for program)

    0.5 Mbyte

    • integrated (for data)

    0.5 Mbyte

    Load memory

     

    • expandable FEPROM, max.

    64 Mbyte

    • integrated RAM, max.

    512 kbyte

    • expandable RAM, max.

    64 Mbyte

    CPU processing times

     

    for bit operations, typ.

    75 ns

    for word operations, typ.

    75 ns

    for fixed point arithmetic, typ.

    75 ns

    for floating point arithmetic, typ.

    225 ns

    Counters, timers and their retentivity

     

    S7 counter

     

    • Number

    2 048

    IEC counter

     

    • present

    Yes

    S7 times

     

    • Number

    2 048

    IEC timer

     

    • present

    Yes

    Data areas and their retentivity

     

    Flag

     

    • Number, max.

    4 kbyte; Size of bit memory address area

    Address area

     

    I/O address area

     

    • Inputs

    4 kbyte

    • Outputs

    4 kbyte

    Process image

     

    • Inputs, adjustable

    4 kbyte

    • Outputs, adjustable

    4 kbyte

    Time of day

     

    Clock

     

    • Hardware clock (real-time)

    Yes

    Operating hours counter

     

    • Number

    16

    Interfaces

     

    Interfaces/bus type

    1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports)

    Number of RS 485 interfaces

    0

    Number of other interfaces

    0

    1. Interface

     

    Interface type

    Integrated

    Physics

    RS 485 / PROFIBUS + MPI

    Functionality

     

    • MPI

    Yes

    • PROFIBUS DP master

    Yes

    • PROFIBUS DP slave

    Yes

    DP master

     

    • Number of DP slaves, max.

    32

    2. Interface

     

    Interface type

    PROFINET

    Physics

    Ethernet RJ45

    Interface types

     

    • Number of ports

    2

    Functionality

     

    • PROFINET IO Controller

    Yes

    • PROFINET IO Device

    Yes

    • PROFINET CBA

    Yes

    • PROFIBUS DP master

    No

    • PROFIBUS DP slave

    No

    Isochronous mode

     

    Isochronous operation (application synchronized up to terminal)

    Yes; Via PROFIBUS DP or PROFINET interface

    Communication functions

     

    PG/OP communication

    Yes

    Data record routing

    Yes

    Global data communication

     

    • supported

    Yes

    S7 basic communication

     

    • supported

    Yes

    S7 communication

     

    • supported

    Yes

    S5 compatible communication

     

    • supported

    Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

    Standard communication (FMS)

     

    • supported

    Yes; Via CP and loadable FB

    Open IE communication

     

    • TCP/IP

    Yes; via integrated PROFINET interface and loadable FBs

    • Number of connections, max.

    46

    • ISO-on-TCP (RFC1006)

    Yes; Via integrated PROFINET interface or CP 443-1 Adv. and loadable FBs

    • Number of connections, max.

    46

    • UDP

    Yes; via integrated PROFINET interface and loadable FBs

    • Number of connections, max.

    46

    Web server

     

    • supported

    Yes

    Number of connections

     

    • overall

    48

    Ambient conditions

     

    Ambient temperature during operation

     

    • min.

    -25 °C; = Tmin

    • max.

    70 °C; = Tmax; @ 60°C for UL/ATEX/FM use

    Ambient temperature during storage/transportation

     

    • min.

    -40 °C

    • max.

    70 °C

    Extended ambient conditions

     

    • relative to ambient temperature-atmospheric pressure-installation altitude

    Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

    Relative humidity

     

    • With condensation, tested in accordance with IEC 60068-2-38, max.

    100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

    Resistance

     

    • against biologically active substances / conformity with EN 60721-3-3

    Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation in corrosive atmospheres!

    • against chemically active substances / conformity with EN 60721-3-3

    Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

    • against mechanically active substances / conformity with EN 60721-3-3

    Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

    Configuration

     

    Know-how protection

     

    • User program protection/password protection

    Yes

    • Block encryption

    Yes; With S7 block Privacy

    Dimensions

     

    Width

    25 mm

    Height

    290 mm

    Depth

    219 mm

    Weights

     

    Weight, approx.

    750 g