Товаров
  
корзина пуста
  • Каталог оборудования Siemens

SIPLUS extreme RAIL analog output modules

  • Заказные данные
    (1)
  • Информационные материалы

    Информационные материалы

    • 4-channel analog output module
    • Approved in accordance with the railway standards EN 50155, EN 15121, EN 50124, EN 50125 and EN 45545 for use in rail traffic
    • Optionally with extremely short conversion times
    • For connecting analog actuators without additional amplifiers
    • Even solves more complex automation tasks

    Область применения

    Analog output modules convert a 16-bit digital value into a current or a voltage and output this to the process. They are suitable, for example, for controlling proportional valves or small servo drives.

    Дизайн

    • Installation on the S7-1500 mounting rail using one single screw
    • Standardized 40-pin front connector using screw terminal or push-in technology
    • Connectable core cross-sections: 0.25 mm2 to 1.5 mm2 (AWG24 to 16), regardless of the front connector used
    • Front connector can be set to prewiring position
    • Front flap with expandable cable compartment, even if fully wired
    • Integrated shielding concept
    • Unambiguous labeling on front of module:
      • Module type
      • Article No.
      • Hardware and firmware version
      • Channel numbers labeling
      • Cabling diagram

    Included in the scope of delivery:

    • Infeed element, shield clamp, and shield terminal
    • One labeling strip for manual labeling
    • One U connector
    • Printed front door

    Функции

    • Uniform display and diagnostics concept:
      • Module status display for ERROR (red LED) and RUN (green LED)
      • Channel status display (channel activated or deactivated, green LED) or diagnostics display (red LED)
      • Display for monitoring the 24 V DC supply voltage (green LED)
    • Supported functions:
      • Consistently high resolution of 16 bits
      • Identification and maintenance data IM0 to IM3
      • Firmware update
      • Channel-specific parameter assignment
      • Channel-granular diagnostics (depends on measurement type/measuring range)
      • Substitute values can be parameterized for the outputs
      • Calibration during runtime
      • Isochronous mode (dependent on the module)

    Технические данные

    Order number

    6AG2532-5HD00-1AB0

    SIPLUS S7-1500 AQ 4xU/I ST T1 RAIL

    General information

     

    Product type designation

    AQ 4xU/I ST

    Product function

     

    • I&M data

    Yes; I&M0 to I&M3

    CiR – Configuration in RUN

     

    Reparameterization possible in RUN

    Yes

    Calibration possible in RUN

    Yes

    Supply voltage

     

    Type of supply voltage

    DC

    Rated value (DC)

    24 V

    Analog outputs

     

    Number of analog outputs

    4; > +60 °C max. 4x ±10 V permissible

    Cycle time (all channels), min.

    3.2 ms; independent of number of activated channels

    Output ranges, voltage

     

    • 0 to 10 V

    Yes

    • 1 V to 5 V

    Yes

    • -10 V to +10 V

    Yes

    Output ranges, current

     

    • 0 to 20 mA

    Yes

    • -20 mA to +20 mA

    Yes

    • 4 mA to 20 mA

    Yes

    Connection of actuators

     

    • for voltage output two-wire connection

    Yes

    • for voltage output four-wire connection

    Yes

    • for current output two-wire connection

    Yes

    Load impedance (in rated range of output)

     

    • with voltage outputs, min.

    1 kΩ; 0.5 kOhm at 1 to 5 V

    • with voltage outputs, capacitive load, max.

    1 µF

    • with current outputs, max.

    750 Ω

    • with current outputs, inductive load, max.

    10 mH

    Errors/accuracies

     

    Basic error limit (operational limit at 25 °C)

     

    • Voltage, relative to output range, (+/-)

    0.2 %

    • Current, relative to output range, (+/-)

    0.2 %

    Interrupts/diagnostics/status information

     

    Diagnostics function

    Yes

    Substitute values connectable

    Yes

    Alarms

     

    • Diagnostic alarm

    Yes

    Diagnostic messages

     

    • Monitoring the supply voltage

    Yes

    • Wire-break

    Yes; Only for output type "current"

    • Short-circuit

    Yes; Only for output type "voltage"

    • Overflow/underflow

    Yes

    Diagnostics indication LED

     

    • RUN LED

    Yes; Green LED

    • ERROR LED

    Yes; Red LED

    • Monitoring of the supply voltage (PWR-LED)

    Yes; Green LED

    • Channel status display

    Yes; Green LED

    • for channel diagnostics

    Yes; Red LED

    • for module diagnostics

    Yes; Red LED

    Potential separation

     

    Potential separation channels

     

    • between the channels and backplane bus

    Yes

    Isolation

     

    Isolation tested with

    707 V DC (type test) and according to EN 50155 (routine test)

    Standards, approvals, certificates

     

    Railway application

     

    • EN 50121-3-2

    Yes; EMC for rail vehicles

    • EN 50121-4

    Yes; EMC for signal and telecommunications systems

    • EN 50124-1

    Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC

    • EN 50125-1

    Yes; Rail vehicles - see ambient conditions

    • EN 50125-2

    Yes; Stationary electrical equipment - see ambient conditions

    • EN 50125-3

    Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)

    • EN 50155

    Yes; Rail vehicles - temperature class T1, horizontal mounting position, salt spray Class ST2

    • EN 61373

    Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B

    • Fire protection acc. to EN 45545-2

    Yes; Rail vehicles - verification on request

    Ambient conditions

     

    Ambient temperature during operation

     

    • horizontal installation, min.

    -40 °C; = Tmin; Startup @ -25 °C

    • horizontal installation, max.

    70 °C; = Tmax; > +60 °C max. 4x ±10 V permissible

    Extended ambient conditions

     

    • relative to ambient temperature-atmospheric pressure-installation altitude

    Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)

    Relative humidity

     

    • With condensation, tested in accordance with IEC 60068-2-38, max.

    100 %; RH incl. condensation/frost (no commissioning under condensation conditions)

    Resistance

     

    • against biologically active substances / conformity with EN 60721-3-3

    Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!

    • against biologically active substances/conformity with EN 60721-3-5

    Yes; Class 5B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against chemically active substances / conformity with EN 60721-3-3

    Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

    • against chemically active substances/conformity with EN 60721-3-5

    Yes; Class 5C3 (RH < 75%) including salt spray according to EN 50155 (ST2). The supplied plug covers must remain in place over the unused interfaces during operation!

    • against mechanically active substances / conformity with EN 60721-3-3

    Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!

    • against mechanically active substances/conformity with EN 60721-3-5

    Yes; Class 5S3 including sand and dust. The supplied plug covers must remain in place over the unused interfaces during operation!

    Decentralized operation

     

    Fast Startup supported

    Yes; 500 ms

    Dimensions

     

    Width

    35 mm

    Height

    147 mm

    Depth

    129 mm

    Weights

     

    Weight, approx.

    310 g

    Other

     

    Note:

    For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776